D3664-US Rev H August 2008 Operators Manual Fort Atkinson, Wisconsin USA Panningen, The Netherlands www.digi-star.com
RF DataLink 4 Extended Range Setup If you are using the extended range radio kit (RS-422) you must go to System, then Defaults, and s
Operators Manual D3664 5 USB Black Box Installation Plug in the Black box into a USB port. Windows will detect the Black box and
RF DataLink 6 Acknowledge – At Mixer – This option is used to send a message to the scale if the operator would like t
Operators Manual D3664 7 Datalink will then receive any completed data from the indicator and send the new data to the indicator. The indicator
RF DataLink 8 Loads Made by Bunk Reader Loads Made by Bunk Reader option allows the bunk reader software to create a specifi
Operators Manual D3664 9 To set the File Paths, from the main menu select [File], [Defaults] and [File Directories]. This will di
RF DataLink 10 Backup Data to – this option will create a duplicate of your data and default to C:\Data. This folder is c
Operators Manual D3664 11 Next set the scale to test mode, to change this enter short cut number (457) and press (Select). Change the option to (Ye
RF DataLink 12 This setting determines whether the RF Datalink will split pens in order to fill your mixer to capacity. When you select
Operators Manual D3664 13 Defaults – Feed Tolerances The weight tolerance settings allow you to establish an accuracy level for the
RF DataLink D3664-H
RF DataLink 14 Auto Add Pen Back on List to Feed This setting allows Datalink to place a pen back in the feeding order when
Operators Manual D3664 15 When you select, [All Loads at one time. PC controls loads] or [All pens and Recipes at one time to the mixer. Mixe
RF DataLink 16 Print Mixer Load Sheet To set the Print Load Sheet Selection, from the main menu select Systems, Defaults, and then the m
Operators Manual D3664 17 Operating the RF DataLink Now send feedings to DataLink and start the process. DataLink will send feeding data to the
RF DataLink 18 feeding process by clicking on the Start button on the Process screen. The feeding process will not begin until you click
Operators Manual D3664 19 Modifying Ration Data To access the Ration data, from the Process screen, click on Rations or select Rations from the Fil
RF DataLink 20 The auto-advance resets the "delay time" counter every time the weight moves out of the tolerance window. I
Operators Manual D3664 21 If you access the pen data from the process screen, the process will be halted until you are done making your
RF DataLink 22 Pens are given priority based on the Feeding Number and the Pen Order sent from the third party software. A Fe
Operators Manual D3664 23 Putting an In-Process Pen back in the Feeding Pens that are InProcess, shows a status of Sent. To place these pens back
Operators Manual D3664
RF DataLink 24 Test Communications To access this screen select File, and then Test Communications. The option will allow yo
Operators Manual D3664 25 Reliability Meter This meter will show how well the scale and the base radio is communicating. The Good Data and Missed
RF DataLink 26 Import Defaults – This is used to replace the current default settings when transferring to a different PC. Reset Mixers fo
Operators Manual D3664 27 Repair Parts – Std. Antenna (P/N 403965 KIT-DATA LINK STANDARD BASE) KEY QTY. PART NO DESCR
RF DataLink 28 Repair Parts – Extend Range Antenna (P/N 403966 KIT-EXTENDED RANGE ANTENNA) KEY QTY PART NO DESCRIPTION 1 1 40401
Operators Manual D3664 RF DataLink Setup 1 Sequence of Operations ... 1 Registering the Software...
RF DataLink Full Load Delay... 15 Defaults – Delivery Sorting ...
Operators Manual D3664 1 RF DataLink Setup Sequence of Operations After installing your software, please follow this section to setup the RF Datali
RF DataLink 2 Radio Antennas The location of the antennas is critical. Check the installation of the antennas and the ante
Operators Manual D3664 3 Fresnel Zone The Fresnel Zone can be thought of as a football-shaped tunnel between two sites that provides